This trainer allows the student to experiment with
and control a Compound Two-Stage
Compressor Application. Compound
multistage systems are typically used where ultra low temperatures are desired
but cannot be economically obtained through the use of a single stage system.
This is because the compression ratios would be too high to get the necessary
evaporating and condensing vapor temperatures. In industrial applications these
systems commonly produce temperatures between –29 deg C to –62 deg C for two
stage systems and lower for three stage systems (down to – 93 deg C)
In compound two-stage refrigeration systems low
temperatures are obtained by using several compressors connected in series to
the same refrigeration circuit. Vapor in the evaporator of a low-temperature
system has a high specific volume at a low temperature. The first stage
compressor is larger than the secondary stage compressor. The refrigerant vapor
is not condensed between compressors and an intercooler lowers the vapor
temperature. In each succeeding stage, the compressor is smaller in order to
handle denser vapors and higher pressures. This increases the performance and
efficiency of low-temperature systems as compared to single-stage systems. The
above diagram shows the layout and operation of the trainer
TRAINER SPECIFICATIONS:
FEATURES:
The components are clearly laid out in a manner similar to a refrigeration
circuit diagram and are mounted onto a mobile steel stand that incorporates a
work surface. The refrigeration circuit is displayed on a colorful
silk-screened diagram. Refrigeration pipes are color coded to indicate the
state of the refrigerant within the circuit. Sight glasses monitor the
refrigerant state along with strategically placed pressure gauges, hand valves
allow the system to be controlled and malfunctions to be introduced, courseware
includes student job sheets.
MAIN COMPONENTS:
Two Compressors (First Stage: 1Hp,
Second Stage:3.0pt/4Hp), one air cooled condenser, one forced fan evaporator with
cabinet (chamber insulation rating of –70 deg C), one intercooler, one
Thermostatic Expansion Valves (TEV), one high side float between stages, one oil
separator, one Receiver, one Filter/dryer, Sight Glasses, one Solenoid Valve,
High Pressure Control, Low Pressure Control, one Thermostat, eight pressure
gauges, one Relief Valve, Set of Hand Valves for Control. Instrument panel has
system controls along with voltmeter and ammeter. Unit will achieve temperature
of between -40 to -45 deg C.
OPTIONAL ACCESSORIES:
RCO-CRS-A: Flow meter for viewing flow rate of
refrigerant.
RCO-CRS-B: Variable speed fan for evaporator or
condenser
RCO-CRS-C: 10 electrical faults with electrical
circuit panel.
RCO-CRS-D: 12 point Digital Temperature meter with
channel selector switch.